การดัดแปลงระบบฉีดสารของเครื่องแก๊สโครมาโตกราฟี
จีราภา กิตธารเมธี - มหาวิทยาลัยเทคโนโลยีพระจอมเกล้าธนบุรี
ชื่อเรื่อง: การดัดแปลงระบบฉีดสารของเครื่องแก๊สโครมาโตกราฟี
ชื่อเรื่อง (EN): Modification of Gas Chromatograph Inlet System
ผู้แต่ง / หัวหน้าโครงการ: จีราภา กิตธารเมธี
บทคัดย่อ (EN): Gas chromatography (GC) is the science of separation. Results are normally shown aschromatograms. Many informations can be derived from the chromatograms, for examples,retention factor (k), plate numbers (N), height equivalent to a theoretical plate (H). The last twoparameters directly relate to the effectiveness of the column as well as of the GC installation.This study is focus on the improvement of the Finigan Splitkplitless injector, especiallythe split system. The injector has been poorly designed and it can only splits the carrier gas butdoes not split the sample. Accordingly, samples are usually overloaded and separation is lesseffective. This fraud is corrected by installation of a new split valve (OSS-2) and the pneumaticflow is redirected. This modification can increase the N more than 6 times. Also, the split outis directed to the detector and use as make up gas. This will help save a huge volume of the makeup gas. However, during injection the split out sample is also directed to the detector. Thisprovides a very benefit in the analysis. As soon as the sample is injected, an immediate detectorresponse is observed and it rill serve as the injection point of which many other parameters(hold-up time, adjusted retention time) can be accurately obtained. Careful measurement of thesplit area and areas of peaks eluted out of the column, it is found that the ratio of these areas canbe used as a representative of the split ratio of the split valve. Thus, it is the first report of thedirect measurement of the split ratio on the gas chromatogram.
บทคัดย่อ: ไม่พบข้อมูลจากหน่วยงานต้นทาง
ภาษา (EN): th
เอกสารแนบ: http://dcms.thailis.or.th/dcms/dccheck.php?Int_code=54&RecId=5870&obj_id=16996
เผยแพร่โดย: มหาวิทยาลัยเทคโนโลยีพระจอมเกล้าธนบุรี
คำสำคัญ (EN): Adjusted retention time
เจ้าของลิขสิทธิ์: มหาวิทยาลัยเทคโนโลยีพระจอมเกล้าธนบุรี
รายละเอียด: Gas chromatography (GC) is the science of separation. Results are normally shown aschromatograms. Many informations can be derived from the chromatograms, for examples,retention factor (k), plate numbers (N), height equivalent to a theoretical plate (H). The last twoparameters directly relate to the effectiveness of the column as well as of the GC installation.This study is focus on the improvement of the Finigan Splitkplitless injector, especiallythe split system. The injector has been poorly designed and it can only splits the carrier gas butdoes not split the sample. Accordingly, samples are usually overloaded and separation is lesseffective. This fraud is corrected by installation of a new split valve (OSS-2) and the pneumaticflow is redirected. This modification can increase the N more than 6 times. Also, the split outis directed to the detector and use as make up gas. This will help save a huge volume of the makeup gas. However, during injection the split out sample is also directed to the detector. Thisprovides a very benefit in the analysis. As soon as the sample is injected, an immediate detectorresponse is observed and it rill serve as the injection point of which many other parameters(hold-up time, adjusted retention time) can be accurately obtained. Careful measurement of thesplit area and areas of peaks eluted out of the column, it is found that the ratio of these areas canbe used as a representative of the split ratio of the split valve. Thus, it is the first report of thedirect measurement of the split ratio on the gas chromatogram.
หากไม่พบเอกสารฉบับเต็ม (Full Text) โปรดติดต่อหน่วยงานเจ้าของข้อมูล

การอ้างอิง


TARR Wordcloud:
การดัดแปลงระบบฉีดสารของเครื่องแก๊สโครมาโตกราฟี
มหาวิทยาลัยเทคโนโลยีพระจอมเกล้าธนบุรี
2544
การวิเคราะห์ปริมาณและชนิดปิโตรเลียมไฮโดรคาร์บอนในตัวอย่างดินตะกอนโดยใช้เทคนิคแก๊สโครมาโตกราฟี-เฟลมไอออไนเซซันดีเทคเตอร์และแก๊สโครมาโตกราฟี-แมสสเปกโตรเมตรี การวิเคราะห์พอลิคลอริเนตเตตไบฟินิล (Polychlorinated Biphenyl, PCBs) ในตัวอย่างดินตะกอนโดยใช้เทคนิคแก๊สโครมาโตกราฟี อิเล็กตรอนแคปเจอร์ดีเทคเตอร์และเทคนิคแก๊สโครมาโตกราฟีแมสสเปคโตรเมตรี การวิเคราะห์สารคอร์ติโคสเตียรอยด์ด้วยเทคนิคไฮเปอร์ฟอร์มานซ์ลิควิดโครมาโตกราฟี ศึกษาเปรียบเทียบวิธีการกำจัดสิ่งเจือปนและการแยกส่วนของการหาปริมาณสารประกอบออร์กาโนคลอลีนในปลานำจือโดยใช้เทคนิคแก๊สโครมาโตกราฟี การวิเคราะห์เชิงปริมาณของไดไฮโดรอาร์ติมิซินินด้วยเทคนิคไฮเปอร์ฟอร์มานลิควิดโครมาโตกราฟี การทำนายค่าเวลาคงค้างของสารนอร์มัลอัลเคน (n-alkanes) ด้วยแก๊สโครมาโตกราฟีบนแคพิลลารีคอลัมน์สองชนิดที่ต่อกันแบบอนุกรม วิธีไฮเพอร์ฟอร์แมนซ์ลิควิดโครมาโตกราฟีเพื่อวิเคราะห์หาปริมาณของยาฆ่าเชื้อรากลุ่มอิมิดาโซลเมื่อมี การหาปริมาณสารประกอบกลุ่มออร์กาโนคลอรีนในน้ำนมโค โดยใช้เทคนิค Liquid-Liquid phase extraction ด้วยเครื่องแก๊สโครมาโตกราฟีอีเล็กตรอนแคปเจอร์ดีเทคเตอร์ (GC-ECD) การจำแนกข้าวหอมไทยโดยใช้แก๊สโครมาโทกราฟิกโพรไฟล์ควบคู่กับวิธีการทางสถิติ การวิเคราะห์สารให้รสชาติและกลิ่นในผลแตงกวาและมะเขือเทศดัดแปลงสารพันธุกรรม
คัดลอก URL
กระทู้ของฉัน
ผลการสืบค้นทั้งหมด โพสต์     เรียงลำดับจาก