ชื่อเรื่อง: การพัฒนาระบบโฟลอินเจคชันเพื่อใช้ในการหาปริมาณไอโอดีนในเกลือเสริมไอโอดีน
ชื่อเรื่อง (EN): A kinetic flow injection method for determination of iodate in iodized salt
ผู้แต่ง / หัวหน้าโครงการ (EN): Kanokrat Lukkanakul
บทคัดย่อ (EN): A kinetic flow injection (FI) method for measuring iodine content in iodized salt was developed. This system was modified from the FI system for analysis of iodine in drinking water that was developed by N. Choengchan. The analytical method is based on the catalytic effect of iodide for the reaction between Ce (IV) and As (III). In Thailand, supplement of iodine is carried out using the iodate form especially in table salt. Therefore, prior to the catalytic analysis, iodate must be first reduced to iodide. Arsenous acid, which already exists in the system, was employed as the reducing agent for iodate. The optimization of the FI system was studied to gain an in-line complete reduction of iodate. Three operational methods were investigated and developed. These methods are (a) full kinetic stopped-FI method, (b) the fixed time stopped-FI method and (c) kinetic continuous-FI method. All methods gave linear calibration plots in the working range of 100 to 6,000 g I/L. For the full kinetic stopped-FI method, the detection limit was 7.5 mg I/kg salt. Average total recovery was 107 % (n=13) with RSD (n=3) of 0.83 %. For the fixed time stopped-FI method, the limit of detection (3) was 1.1 mg I/kg salt. The method gave average total recovery as 114 % (n=13) and provided satisfactorily low % RSD (n=10) of 0.63 %. For the kinetic continuous-FI method, the detection limit (3) was found to be 1.3 mg I/kg salt. Average total recovery was 111 % (n=13). This technique gave reasonably good repeatability in term of RSD as 0.17 % (n=10). Method validation for ten iodized salt samples and three synthetic samples showed no significant difference between iodine contents obtained from four methods (i.e. the full kinetic stopped-FI method, the fixed time stopped-FI method, the kinetic continuous-FI method and the colorimetric-FI method). This agreement implied that all proposed operational methods developed in this work are applicable. However, for real application in commercial iodized salt, the kinetic continuous-FI method was chosen. This method provided the highest sample throughput of 90 samples/h.
บทคัดย่อ: ไม่พบข้อมูลจากหน่วยงานต้นทาง
ภาษา (EN): th
เอกสารแนบ: http://dcms.thailis.or.th/dcms/dccheck.php?Int_code=126&RecId=1121&obj_id=1406
เผยแพร่โดย: มหาวิทยาลัยมหิดล
คำสำคัญ (EN): Sandell-Kolthoff reaction
เจ้าของลิขสิทธิ์: มหาวิทยาลัยมหิดล
รายละเอียด: A kinetic flow injection (FI) method for measuring iodine content in iodized salt was developed. This system was modified from the FI system for analysis of iodine in drinking water that was developed by N. Choengchan. The analytical method is based on the catalytic effect of iodide for the reaction between Ce (IV) and As (III). In Thailand, supplement of iodine is carried out using the iodate form especially in table salt. Therefore, prior to the catalytic analysis, iodate must be first reduced to iodide. Arsenous acid, which already exists in the system, was employed as the reducing agent for iodate. The optimization of the FI system was studied to gain an in-line complete reduction of iodate. Three operational methods were investigated and developed. These methods are (a) full kinetic stopped-FI method, (b) the fixed time stopped-FI method and (c) kinetic continuous-FI method. All methods gave linear calibration plots in the working range of 100 to 6,000 g I/L. For the full kinetic stopped-FI method, the detection limit was 7.5 mg I/kg salt. Average total recovery was 107 % (n=13) with RSD (n=3) of 0.83 %. For the fixed time stopped-FI method, the limit of detection (3) was 1.1 mg I/kg salt. The method gave average total recovery as 114 % (n=13) and provided satisfactorily low % RSD (n=10) of 0.63 %. For the kinetic continuous-FI method, the detection limit (3) was found to be 1.3 mg I/kg salt. Average total recovery was 111 % (n=13). This technique gave reasonably good repeatability in term of RSD as 0.17 % (n=10). Method validation for ten iodized salt samples and three synthetic samples showed no significant difference between iodine contents obtained from four methods (i.e. the full kinetic stopped-FI method, the fixed time stopped-FI method, the kinetic continuous-FI method and the colorimetric-FI method). This agreement implied that all proposed operational methods developed in this work are applicable. However, for real application in commercial iodized salt, the kinetic continuous-FI method was chosen. This method provided the highest sample throughput of 90 samples/h.
หากไม่พบเอกสารฉบับเต็ม (Full Text) โปรดติดต่อหน่วยงานเจ้าของข้อมูล

การอ้างอิง


TARR Wordcloud:
การพัฒนาระบบโฟลอินเจคชันเพื่อใช้ในการหาปริมาณไอโอดีนในเกลือเสริมไอโอดีน
Kanokrat Lukkanakul
มหาวิทยาลัยมหิดล
2546
การพัฒนาระบบโฟลอินเจกวันคัลเลอริเมตรีแบบอัตโนมัติที่ใช้การแยกโดยการแพร่ของแก๊สสำหรับการหาปริมาณเอทานอล การวิเคราะห์ไอโอไดด์ในผลิตภัณฑ์ยาด้วยระบบโฟลอินเจคชันร่วมกับการใช้ก๊าซดิฟฟิวชันโดยอาศัยปฏิกิริยาของไอโอดีนและน้ำแป้ง การพัฒนาและการสร้างระบบโฟลอินเจคชันอะนาลิซีสสำหรับวิเคราะห์หาปริมาณแคดเมียม ทองแดง เหล็ก การพัฒนาวิธีโฟลว์อินเจคชันและซีเควนเชียลอินเจคชันสำหรับการหา ปริมาณแคดเมียมโดยใช้โรดามีนบี การพัฒนาระบบโฟลอะนาลิซีสสำหรับไนโตรฟีนอล ควินีน แคลเซียมและแมกนีเซียม การดัดแปรเกลือโดยใช้การทำแห้งแบบพ่นฝอยและใช้กลิ่นเสริมรสเค็ม การพัฒนาโฟลว์อินเจกชันอะนาลิซิสร่วมกับแอมเพอโรเมตริกไบโอเซนเซอร์ที่ดัดแปรสำหรับการหาปริมาณกลูโคส การพัฒนาวิธีการวิเคราะห์ปริมาณธาตุในตัวอย่างที่มีเกลือปริมาณสูงโดยใช้เทคนิคอะตอมมิกแอบซอร์พชันและอะตอมมิกอิมิสชันสเปกโทรเมตรีหลังผ่านการขจัดสารรบกวน การเพิ่มความเข้มข้นโปรตีนและการลดปริมาณเกลือในน้ำนึ่งปลาโดยใช้กระบวนการอัลตราฟิลเตรชันและไดอะฟิลเตรชัน ความสัมพันธ์ระหว่างราคาน้ำมันกับปริมาณการส่งออกสินค้าทางอากาศของประเทศไทยโดยใช้วิธีเทรสโฮลด์โคอินทิเกรชัน
คัดลอก URL
กระทู้ของฉัน
ผลการสืบค้นทั้งหมด โพสต์     เรียงลำดับจาก